Modular IO Controller

Modbus RTU Supported | -25℃~+75℃ | Hardware Watchdog | Flame retardant rating

  • Price:
  • $
  • Model:
  • IO0080/8000/0440/4040/0404
  • Quantity:
  • - +

Customers Also Bought More+

Product Name:Modular IO Controller

  • Model:IO0080/8000/0440/4040/0404

USR-IO Controller | Eatendable Remote I/O Module


The USR-IO series is an advanced and expandable I/O controller lunched by PUSR, allowing for the desired quantity of I/O through combinations of the different model. When used with PUSR's M100 or M300, it enables remote control of IO devices. With its unique hardware design, it saves time on installation or removal, featuring push-in terminals that allow users to connect on-site without the need for tools. All these designs makes it an ideal solution for a variety of industrial data acquisition applications.



Advanced Features


Ordering Guide


PUSR provides 5 different models of expansion units for users to choose from, please see the table for specific differences between different modules.



Modbus RTU Supported


The USR-IO modular controller supports standard Modbus RTU for data acquisition and control, making integration into control systems extremely straightforward.


         

Industrial Grade Design


  • EMC Protection: Level 3, IEC 61000

  • Wide Operating Temp: -25℃~+75℃

  • Hardware Watchdog: Supported

  • Flame retardant rating: V0, burning stops within 10 seconds on a vertical part allowing for drops of plastic that are not inflames.



Cable Wiring Diagram-Dry Contacts for DI


For dry contacts device, users need to connect the USR-IO's power in the whole circuit to detect the status of IO devices, such as detecting the status of switches, buttons, etc.



Cable Wiring Diagram-Wet Contacts for DI


For wet contact devices, they output voltage signals such as high and low levels, pulses, etc. These devices already have an internal power source and do not require additional power supply. They can be directly connected to the terminals of the USR-IO controller, such as infrared detection, liquid level detection, smoke detection, etc. For the USR-IO controller, the input voltage range is 9-36V. If it exceeds this range, the device's status cannot be detected correctly.


                   


Cable Wiring Diagram for 2-wire 4-20ma Sensor


For two-wire 4-20mA sensors, the sensor itself only has 2 wiring terminals: power + and signal -. These terminals serve both as power supply and signal transmission channels. In this scenario, connecting the sensor's power + to the USR-IO's power + and the sensor's signal - to the USR-IO's AI interface, while connecting USR-IO's COM to the power -, completes the setup.


        

 

Cable Wiring Diagram for 4-wire 4-20ma Sensor


For two-wire 4-20mA sensors, the sensor itself only has 2 wiring terminals, serving as both power supply and signal transmission channels. In this scenario, connecting the AI terminal to the power supply circuit enables the detection of the analog signal.


         


Cable Wiring Diagram for Analog Output(0-10V)


In the AO loop, there is no need to connect to a power source.


         


Cable Wiring Diagram for Analog Output(4-20 mA)


In the AO loop, there is no need to connect to a power source.


         


Cable Wiring Diagram for DO


Applicable when the current is less than 3A. If connecting high-power loads, replace the lighting fixture in the diagram with a relay or an AC contactor.


       


Cable Wiring Diagram for Power Supply


When using multiple IO controllers in combination, only one power supply is supported. Please do not connect multiple power supplies for power input.


         


Detail & Dimension


  • Reload button: Press and hold on for 3~15s to reset the device to factory settings.

  • Dimension: 79.6*28*110mm

          

Used in Conjunction with M100/M300


The USR-IO can be used with PUSR's M100 or M300, which can enable remote control of IO devices.And screwdrivers and other tools are not required for any part of the hardware installation, which can reduces the amount of time required for installation and removal.

USR-M100

USR-M300


         


Tool-Free Cable Wiring


The USR-IO modular controller uses direct-insertion spring terminal blocks, making wiring more convenient.



Automatic Production Line Transformation


Integrating the IO controller into automated production line equipment, gathering and controlling device actions via RS485, effectively reduces labor costs and enables unmanned supervision of the production line.




Smart Home Application


Connecting the water heater, access control system, motorized curtains, lighting fixtures, and other devices to the IO controller, and integrating them with the control host through RS485 Modbus RTU, enables intelligent home automation and supervision.

Items

Description

Interface

RS485

Default: 9600, NONE, 8, 1

Options for band rate: 4800, 9600, 115200, 230400

Parity bit: NONE, EVEN, ODD

Data bits: 8

Stop bit(s): 1, 2

Physical Specification

Dimensions

79.6*58*110(mm)

Installation

DIN rail mounting & Panel mounting

Status LEDs

POW

Steady on: Power supply is normal

Off: No power supply or abnormal power supply

WORK

Blinking: Power is on, and the device is ready. System is booted up and running

DO

Steady on: The channel output is activated

DI

Steady on: The channel is activated input signal

Power

2-pin socket

DC:12-24V

Protection

EMC Protection

Level 3, IEC 61000

Watchdog

Hardware & Software watchdog

 

Flame retardant rating

V0, burning stops within 10 seconds on a vertical part allowing for drops of plastic that are not inflames.

Temperature

Operation temperature

-25℃ ~ +75℃

Storage temperature

-40℃ ~ +105℃

Humility

Operation humility

5%~95% (non-condensing)

I/O

DI

Digital opto-isolated input (0 -2 V detected as logic low,9 -36 V detected as logic high)

AI

Analog input 4-20mA

DO

Relays, the endurance is 100,000 operations.

DC contacts rating @R (at resistive load) 3A / 30V DC.

AC contacts rating @R (at resistive load) 3A / 250V AC, NO

AO

Analog output:voltage output: 0-10V,current output: 4-20mA

Modbus

Slave address

Range: 1~255

Default: 1

Email contact

WhatsApp

Use WhatsApp

Contact Sales

TOP

服务热线